Room capacity and setup calculator

See how many people fit in a room for each setup style, or how much space you need for your headcount, after the stage, AV and stations take their share.

Your room

Example values
Setup style

Rows of chairs facing a stage or screen. Every style is in the table.

Room size
Space taken by other things

Enter 0 for no stage.

Kept free across the stage width.

Tech table, screens, rear projection or camera risers.

About 100 sq ft each, with the queue.

About 60 sq ft each: a 6 ft table, staff behind, visitors in front.

Cross aisles, wider accessible routes, pillars and fire exits. The per-person rules already include normal aisles.

189 to 237theater

Theater capacity (planning estimate)

189 to 237

People in 1,897 sq ft of usable space (176 m²), from a 2,400 sq ft room.

The fire marshal's number is the legal limit. These are planning rules of thumb. Ask the venue for the posted occupancy for your setup, and never go over it.

Capacity by setup style

StyleSq ft per personPeople
Theater (selected)8 to 10189 to 237
Classroom18 to 2094 to 105
Banquet, rounds of 1010 to 12150 to 180 (15 tables)
Banquet, rounds of 812 to 14128 to 152 (16 tables)
Cocktail or reception6 to 8237 to 316
Boardroom20 to 2575 to 94
U-shape25 to 3063 to 75

Usable space

  • Room2,400 sq ft
  • Less stage and clear space192 sq ft
  • Less aV and production100 sq ft
  • Less extra aisles (10%)211 sq ft
  • Usable for people1,897 sq ft

The maths runs in your browser and we don't save your inputs. They're kept in the page URL so you can share the result.

When to use software instead

A calculator tells you roughly what fits. To place every table, check sightlines and share a scaled floor plan with the venue, use a diagramming tool. See our event diagramming software guide, and the venue sourcing guide for finding rooms that fit.

How it works

The square-feet-per-person figures below are commonly used planning rules of thumb, not codes or standards. They give a range: the roomier end for comfort, the tighter end for the most you could plan for. The fire marshal's posted capacity for the room is always the legal limit.

Usable area

(length × width − stage − AV − stations − tabletops) × (1 − extra aisle allowance)

The stage counts its width times its depth plus the clear space in front. Buffet or bar stations count about 100 sq ft each and sponsor tabletops about 60 sq ft each.

Example: (2,400 sq ft − 292 sq ft) × (1 − 10%) = 1,897 sq ft

Capacity

usable area ÷ square feet per person, rounded down

Banquet capacity rounds down to whole tables.

Example: theater: 1,897 sq ft ÷ 10 to 8 = 189 to 237 people

Space needed for a headcount

headcount × square feet per person ÷ (1 − extra aisle allowance) + stage, AV and stations

Planning rules of thumb used

  • Theater8 to 10 sq ft (0.7 to 0.9 m²)
  • Classroom18 to 20 sq ft (1.7 to 1.9 m²)
  • Banquet, rounds of 1010 to 12 sq ft (0.9 to 1.1 m²)
  • Banquet, rounds of 812 to 14 sq ft (1.1 to 1.3 m²)
  • Cocktail or reception6 to 8 sq ft (0.6 to 0.7 m²)
  • Boardroom20 to 25 sq ft (1.9 to 2.3 m²)
  • U-shape25 to 30 sq ft (2.3 to 2.8 m²)

Boardroom and U-shape layouts stop working well above about 30 and 40 people. Accessibility needs, long sessions and laptops all push toward the roomier end.

FAQ

How do you calculate room capacity for an event?
Measure the room's length and width to get the area, subtract space for the stage, AV, buffets and anything else on the floor, then divide what's left by a square-feet-per-person figure for your setup style. Theater needs the least space per person and U-shape the most. Then check the result against the venue's posted occupancy.
How many square feet per person do you need for an event?
Common planning rules of thumb are 8 to 10 square feet per person for theater seating, 18 to 20 for classroom, 10 to 14 for banquet rounds, 6 to 8 for a standing reception, and 20 to 30 for boardroom or U-shape. Use the roomier end when guests have bags, there are wheelchairs, or the program is long.
Is room capacity the same as the fire code limit?
No. Planning capacity is how many people fit comfortably in a given setup. The fire code limit, set by the local fire marshal or building authority, is the legal maximum occupancy, and it depends on exits, sprinklers and use. Your setup can hold fewer people than the legal limit but never more.
How many people fit at a banquet round table?
A 60 inch round seats 8 comfortably and a 72 inch round seats 10. Planners usually allow about 10 to 12 square feet per person for rounds of 10 and 12 to 14 for rounds of 8, which includes the table, chairs and service aisles. Round your headcount up to whole tables.
How big a room do I need for 100 people?
Using common planning rules, 100 people need about 800 to 1,000 square feet in theater style, 1,000 to 1,200 for rounds of 10, 600 to 800 for a standing reception and 1,800 to 2,000 for classroom, before you add a stage, AV or buffets. Switch the calculator to "How much space?" for your exact setup.
How do you convert square meters per person for event space?
One square meter is about 10.76 square feet, so divide the square-feet figure by 10.76. Theater seating at 8 to 10 square feet per person is roughly 0.74 to 0.93 square meters, and a reception at 6 to 8 square feet is about 0.56 to 0.74. The calculator converts both ways.